General Purpose Silicon Sensors (Series 0)
Series
0 photodiodes are designed for operation at up to 30V reverse bias voltage
for applications where low capacitance and high speed are important. These
detectors are tailored for peak responsivity in the 780-950 nm range but
are successfully used for pulsed applications throughout the spectral
range from 430-1064 nm.
Electrical / Optical Specifications
Characteristics measured at 22°C (±2) ambient, and a reverse
bias of 30 volts, unless otherwise stated.
| Type No. |
Active Area | Responsivity A/W λ = 900 nm |
Dark Current nA |
NEP WHz-½ λ = 900 nm Typ. |
Capacitance pF |
Risetime ns λ = 900 nm RL = 50 Ω Typ. |
Package | ||||
| mm2 | mm | Min | Typ. | Max. | Typ. | Vr = 0 V Typ. |
Vr = 30V Max |
||||
| OSD1-0 | 1 | 1.13 dia | 0.47 | 0.54 | 3 | 1 | 4.5 x 10-14 | 12 | 3 | 10 | 1 |
| OSD5-0 | 5 | 2.52 dia | 0.47 | 0.54 | 10 | 5 | 1.0 x 10-13 | 50 | 8 | 8 | 3 |
| OSD15-0 | 15 | 3.8 x 3.8 | 0.47 | 0.54 | 15 | 8 | 1.3 x 10-13 | 150 | 20 | 9 | 3 |
| OSD35-0 | 35 | 5.9 x 5.9 | 0.47 | 0.54 | 30 | 12 | 1.6 x 10-13 | 350 | 46 | 12 | 8 |
| OSD50-0 | 50 | 7.98 dia | 0.47 | 0.54 | 50 | 15 | 1.7 x 10-13 | 500 | 65 | 13 | 9 |
| OSD100-0 | 100 | 11.3 dia | 0.47 | 0.54 | 70 | 30 | 2.5 x 10-13 | 1000 | 130 | 19 | 13 |
| Type No. |
Active Area (Total) |
Responsivity A/W λ = 900 nm |
Dark Current nA |
NEP WHz-½ λ = 900 nm Typ. |
Capacitance pF | Risetime ns λ = 900 nm RL = 50 ω Typ. |
Crosstalk % λ = 900 nm |
Package | ||||||
| mm2 | mm | Sep. mm |
Min. | Typ. | Max. | Typ. | Vr = 0V Typ. |
Vr = 30V Max. |
Max. | Typ. | ||||
| Q 7-0 | 7 | 2.99 dia | 0.2 | 0.47 | 0.54 | 15 | 4 | 9.0 x 10-14 | 20 | 4 | 10 | 5 | 1 | 7 |
| QD50-0 | 50 | 7.98 dia | 0.2 | 0.47 | 0.54 | 30 | 15 | 1.3 x 10-13 | 125 | 18 | 9 | 5 | 1 | 10 |
| QD100-0 | 100 | 11.3 dia | 0.2 | 0.47 | 0.54 | 50 | 25 | 2.2 x 10-13 | 250 | 30 | 10 | 5 | 1 | 11 |
Type No. |
No. of Elements |
Array Dimensions |
Responsivity A/W Λ = 900 nm |
Dark Current nA |
NEP WHz-½ Λ = 900 nm Typ. |
Capacitance pF |
Risetime ns Λ = 900 nm RL = 50 Ω Typ. |
Package |
||||||
Area mm2 |
Width mm |
Lgth. mm |
Sep. mm |
Min. |
Typ. |
Max. |
Typ. |
Vr = 0V Typ. |
Vr = 30V Max. |
|||||
| LD2A-0 | 2 |
1.00 |
2.00 |
0.5 |
0.05 |
0.47 |
0.54 |
5 |
1 |
4.5 x 10-14 |
12 |
3 |
15 |
4 |
| LD2B-0 | 2 |
2.02 |
1.42 |
1.42 |
0.45 |
0.47 |
0.54 |
10 |
2 |
6.3 x 10-14 |
22 |
4 |
11 |
4 |
| LD20-0 | 20 |
3.6 |
4.0 |
0.9 |
0.05 |
0.47 |
0.54 |
25 |
4 |
9.0 X 10-14 |
37 |
7 |
10 |
16 |
| LD35-0 | 35 |
4.42 |
4.6 |
0.96 |
0.03 |
0.47 |
0.54 |
30 |
5 |
1.0 x 10-13 |
45 |
8 |
10 |
17 |
| Matrix Arrays (Values given are per element unless otherwise stated) | ||||||||||||||
| MD25-0 | 5 x 5 |
7.99 |
2.7 |
1.7 |
0.1 |
0.47 |
0. 54 |
200 |
4 |
8.6 x 10-14 |
92 |
15 |
9 |
18 |
Note: Recommended operating voltage range 0 to 30 volts, for all Series 0 Detectors.
Highlighted items are Centronic standard products generally available from stock
Due to our policy of continued development, specifications are subject to change without notice.