Detection of Gamma, Beta radiation with a range of thin wall Glass Detectors including detectors for measuring contaminated liquids.
| Type |
Sensitivity
|
Operating Voltage V | Min. Plateau Length V | Max. Slope % / V | Active Length mm | Life Expectation Counts | Sensitivity cpm/mR/hr | Shielded Background cpm | Liquid Capacity ml | Temp. Range °C | Temp. Coeff. V / °C | Wall / Window Density mg/cm2 | ||
|
Band
|
||||||||||||||
|
α
|
β
|
γ
|
||||||||||||
| B6H |
|
•
|
•
|
370
|
100
|
0.15
|
64
|
1010
|
2000
|
15
|
-
|
-55 to +60
|
0.2
|
25 to 35
|
| B12H |
|
•
|
•
|
370
|
100
|
0.15
|
123
|
1010
|
5600
|
30
|
-
|
-55 to +60
|
0.2
|
25 to 35
|
| B12N |
|
•
|
•
|
675
|
120
|
0.10
|
120
|
1010
|
5000
|
30
|
-
|
-60 to +70
|
0.2
|
25 to 35
|
| B6T |
|
•
|
•
|
675
|
100
|
0.10
|
60
|
1010
|
-
|
-
|
-
|
-60 to +70
|
0.1
|
25 to 35
|
| With compensating filter | ||||||||||||||
| B6TS |
|
|
•
|
675
|
100
|
0.10
|
60
|
1010
|
2700
|
-
|
-
|
-60 to +70
|
0.1
|
-
|
| Liquid Sampling | ||||||||||||||
| M6H |
Liquid
|
370
|
100
|
0.15
|
60
|
1010
|
-
|
16
|
9
|
-10 to +50
|
0.2
|
25 to 35
|
||
| M6H/100 |
500
|
200
|
0.15
|
60
|
1010
|
2880
|
100
|
100
|
-10 to +50
|
0.2
|
25 to 35
|
|||
| M2Na ‚ |
510
|
90
|
0.15
|
21
|
1010
|
-
|
20
|
3.5
|
-10 to +50
|
0.2
|
25 to 35
|
|||
| M2H ‚ |
370
|
100
|
0.15
|
20
|
1010
|
-
|
7
|
3.5
|
-55 to +60
|
0.2
|
25 to 35
|
|||
| Notes ‚ = Supplied with waterproof rubber jacket ◊ = Counting rate at 10 mGy /h ♦ = 137Cs |
||||||||||||||