ion chambers are generally used in reactor control instrumentation for
measurement of neutron flux. When designed with gamma compensation, they
are ideally suited for the high mixed fluxes found near a reactor, being
the only detectors, which are capable of discriminating against gamma
fluxes in these environments.
| TYPE |
OPERATING
TEMP (°C) |
NEUTRON
SENSITIVITY (A/nv) |
OPERATING
VOLTAGE (Volts) |
DIMENSIONS
|
CHAMBER TYPE
/ APPLICATION |
|
|
DIAMETER
(mm) |
LENGTH |
|||||
| IN5A | 90 | 1.2e-14 | 1000 | 89 | 330 | CANDU AND CANDU TYPE REACTOR |
| IN5C | 200 | 8.75e-15 | 1000 | 89 | 330 | SIZEWELL B PWR |
| IN28 | 200 | 7e-14 | 1500 | 65 | 665 | KWU TYPE REACTOR |
| IN29 | 200 | 5.5e-14 | 1000 | 65 | 505 | GAMMA COMPENSATED KWU TYPE REACTOR |
| IN34 | 200 | 2.64e-14 | 1000 | 89 | 505 | |
| IN35 | 200 | 2.64e-14 | 1000 | 89 | 550 | GAMMA COMPENSATED / MAPLE X |
| IN36 | 200 | 5.5e-14 | 1000 | 77 | 337 | - |
| RC6 | 200 | 5e-15 to 2.14e-14 | 600 | 90 | 230 | GAMMA COMPENSATED |
| RC7 | 200 | 7e-15 to 2.92e-14 | 800 | 90 | 230 | UNCOMPENSATED / RESEARCH / MAGNOX REACTORS |